8
7
6
5
3
2
REVISION HISTORY
ZONE
REV
DESCRIPTION
C5
D
PER PCP #10-0214: 1. UPDATED FOR BEST PRACTICES 2. 1.000 THROUGH WAS 1.500 THROUGH
C7
E
C5
F
1 NAME/DATE
APPD/DATE
RL 7/28/2010
JW 9/14/2010
REVISED PER PCP 11-0573: DIM .141 WAS .125 1.
JPR 11/15/2011
JW 11/17/2011
REVISED PER EN 714377 1. 1.500 THRU WAS 1.000 THRU
FRM 1/17/2013
JW 2/25/2013
METAL DOOR
9
D
4
D
.156 1.125
TRIM BORDER LINE
2.750 SECTION A-A 5
5
5
CL OF BEVEL
HINGE EDGE
5
HINGE EDGE
HINGE EDGE 2X .141 THIS SIDE ONLY 1.500 2X
.500 THRU
1.500 THRU
C
9.000 2X #8-32 TAPPED HOLE
2X 6.625
.125 THIS SIDE ONLY
7.500 1.063
9
5.375
.313
4.000 10 WIRE ACCESS
2.469
6 CL OF LEVERS, LOCKBODY, & STRIKE
C
1.000 THIS SIDE ONLY
+.031 2.250 - .000
2X .156 2X FULL R.
2.625
REV F
A
1.625±.005
+.031 THRU 2.125 - .000
1
A
38" (REF) AFF (36" (REF) AFF FOR ADA)
OUTSIDE
B
FINISHED FLOOR
+.031 1.125 - .000
BEVEL SIDE
.313 THRU
OUTSIDE
INSIDE
INSIDE R.H. DOOR
L.H. DOOR
4. 5 5. 6. 6 7. 8. 9 9.
10 10. 11. 12 12.
3.010
4486
5
3.500
O/S TRIM
4.500
AUTHORIZED PREFIXES KP
I/S TRIM
10.170 11.152
BACKSET DEFINITION
DOOR HANDING INSIDE R.H. L.H.
BACKSET
11.947
OUTSIDE
6 CL OF LEVERS, LOCKBODY, & STRIKE
TOP OF DOOR VERTICAL CL
INSIDE CL OF BEVEL
L.H.R.B.
OUTSIDE R.H.R.B
Sargent Manufacturing Company 100 Sargent Drive New Haven, CT 06511
1.777 O/S LEVER
OUTSIDE L.H. TRIM SHOWN 12
13
INSIDE L.H. TRIM SHOWN 12
I/S LEVER
13
DOOR MANUFACTURERS TEMPLATE: KP SERIES TRIM METAL DOOR 10 LINE BORED LOCK
SHEET 1 OF 2
RELEASE DATE
25-FEB-13
TEMPLATE NO.
A
4486 F
Form Rev. 30Jan2006
MAT'L
13 13.
FOR ELECTROLYNX APPLICATIONS, REFER TO MCKINNEY TRANSFER DEVICE CATALOG. VERTICAL CENTERLINE IS REFERENCED FROM THE CENTERLINE OF THE BEVEL. (INDUSTRY STANDARD BEVEL IS 1/8 INCH IN 2 INCHES.) CONSULT THE AUTHORITY HAVING JURISDICTION (AHJ) TO VERIFY THE RECOMMENDED MOUNTING HEIGHT ABOVE THE FINISHED FLOOR (AFF). LIMITATIONS IN THE DOOR CONSTRUCTION PROCESS MAY REQUIRE SOME HOLES TO BE FIELD-LOCATED USING THE PHYSICAL PART AS A TEMPLATE. STANDARD TOLERANCE OF ± .015 APPLIES TO ALL DOOR PREPARATION REQUIREMENTS, UNLESS OTHERWISE SPECIFIED. DOOR REINFORCEMENT IS RECOMMENDED TO IMPROVE (SURFACE MOUNTED) FASTENER HOLDING POWER AND CRUSH RESISTANCE (WHEN THRU-BOLTING IS EMPLOYED). CONSTRUCTION TECHNIQUES SHOULD REFLECT INDUSTRY BEST PRACTICES (I.E. WDMA, SDI) AND AUTHORIZED METHODS WHERE LABEL SERVICE (I.E. UL, W-H) IS IN EFFECT. WIRE RACEWAY AREAS SHOULD BE FREE OF OBSTRUCTIONS & SHARP EDGES TO PROTECT WIRES FROM CUTS & ABRASIONS. CAREFULLY NOTE WHICH FEATURES ARE OPTIONAL, (WHETHER THE FEATURE APPLIES TO BOTH SIDES OF THE DOOR AND/OR IF A DEPTH APPLIES.) MAXIMUM PRODUCT DIMENSIONS ARE SHOWN FOR THE PURPOSE OF VERIFYING FITMENT WITH DOOR FRAME STOPS, DOOR STILE SIZE & LIGHT/LOUVER KITS. IF OPTIONAL LEVERS OR ROSES ARE USED REFERENCE THE RELATED PRODUCT DIMENSIONS TO VERIFY THE FITMENT REQUIREMENTS.
5
DWG No.
NOTES: 1. DRAWING IS NOT TO SCALE. 2. PREPARATION DETAILS ARE IN SUPPLEMENT TO ANSI/BHMA A156.115 AND/OR A115W. 3. REFERENCE STRIKE TEMPLATE FOR DETAILS TO PREPARE FRAME.
A
2X
2.469
SH
2.750 FROM CL OF BEVEL (MINIMUM ALLOWABLE BACKSET)
INTERPRET DRAWING PER ANSI Y14.5M -1994 UNLESS OTHERWISE SPECIFIED ALL DIMENSION ARE IN INCHES. .XX .01 TOLERANCE .XXX .005 ANGLE 1 FRACTION 1/64
CONFIDENTIAL
8
7
6
5
4
3
THIS DOCUMENT IS THE CONFIDENTIAL PROPERTY OF SARGENT MANUFACTURINGAND IS NOT TO BE REPRODUCED, USED OR DISCLOSED BY ANYONE WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE SARGENT MANUFACTURING COMPANY.
2
DRAWN BY/DATE
SARGENT Manufacturing Company
SG
5/16/08
TCZ
5/21/08
ART.
MJF
5/13/08
TITLE:
CCH
5/22/08
-
-
LB
5/30/08
CHECKED BY/DATE MFG ENG/DATE
FNL APPROVAL/DATE FNL APPROVAL/DATE PROD CTRL/FNL REL
100 Sargent Drive New Haven, CT 06511
KP SERIES BORED LOCK
DOOR MANUFACTURERS TEMPLATE
SIZE DWG No.
D
SCALE:
4486 1:2
1
REV F
SHEET:
1 of 2
8
7
6
5
4
3
2
REVISION HISTORY
1
ZONE
REV
DESCRIPTION
NAME/DATE
APPD/DATE
-
-
SEE SHEET 1
-
-
WOOD DOOR
D
D
+.016 .156 - .000 1.125
TRIM BORDER LINE
2.750 SECTION A-A HINGE EDGE
5
CL OF BEVEL
5
HINGE EDGE
5
5
HINGE EDGE
1.500
2X
2X .125 1.250 THIS SIDE ONLY
.500 THRU
1.500 THRU .500
C
9.000 7.500
.313
2.50
6 CL OF LEVERS, LOCKBODY, & STRIKE
A
A
2.750 FROM CL OF BEVEL (MINIMUM ALLOWABLE BACKSET)
2.469
+.031 2.250 - .000 2X
38" (REF) AFF (36" (REF) AFF FOR ADA)
1.625
2.625
+.031 1.125 - .000
FINISHED FLOOR
BEVEL SIDE L.H. DOOR
5 5. 6. 6 7. 8. 9.
10 10. 11. 12 12.
.313 THRU
INSIDE
OUTSIDE INSIDE R.H. DOOR 5
5
3.010
3.500
O/S TRIM
4.500
AUTHORIZED PREFIXES KP
I/S TRIM
10.170 11.152
BACKSET DEFINITION BACKSET
11.947 6 CL OF LEVERS, LOCKBODY, & STRIKE
DOOR HANDING INSIDE R.H. L.H. OUTSIDE
TOP OF DOOR VERTICAL CL
INSIDE CL OF BEVEL
L.H.R.B.
OUTSIDE R.H.R.B
Sargent Manufacturing Company 100 Sargent Drive New Haven, CT 06511
1.777 O/S LEVER
OUTSIDE L.H. TRIM SHOWN 12
INSIDE L.H. TRIM SHOWN 12
13
I/S LEVER
13
DOOR MANUFACTURERS TEMPLATE: KP SERIES TRIM WOOD DOOR 10 LINE BORED LOCK
SHEET 2 OF 2
RELEASE DATE
25-FEB-13
TEMPLATE NO.
A
4486 F
Form Rev. 30Jan2006
MAT'L
A
13 13.
FOR ELECTROLYNX APPLICATIONS, REFER TO MCKINNEY TRANSFER DEVICE CATALOG. VERTICAL CENTERLINE IS REFERENCED FROM THE CENTERLINE OF THE BEVEL. (INDUSTRY STANDARD BEVEL IS 1/8 INCH IN 2 INCHES.) CONSULT THE AUTHORITY HAVING JURISDICTION (AHJ) TO VERIFY THE RECOMMENDED MOUNTING HEIGHT ABOVE THE FINISHED FLOOR (AFF). LIMITATIONS IN THE DOOR CONSTRUCTION PROCESS MAY REQUIRE SOME HOLES TO BE FIELD-LOCATED USING THE PHYSICAL PART AS A TEMPLATE. STANDARD TOLERANCE OF ± .015 APPLIES TO ALL DOOR PREPARATION REQUIREMENTS, UNLESS OTHERWISE SPECIFIED. DOOR REINFORCEMENT IS RECOMMENDED TO IMPROVE (SURFACE MOUNTED) FASTENER HOLDING POWER AND CRUSH RESISTANCE (WHEN THRU-BOLTING IS EMPLOYED). CONSTRUCTION TECHNIQUES SHOULD REFLECT INDUSTRY BEST PRACTICES (I.E. WDMA, SDI) AND AUTHORIZED METHODS WHERE LABEL SERVICE (I.E. UL, W-H) IS IN EFFECT. WIRE RACEWAY AREAS SHOULD BE FREE OF OBSTRUCTIONS & SHARP EDGES TO PROTECT WIRES FROM CUTS & ABRASIONS. CAREFULLY NOTE WHICH FEATURES ARE OPTIONAL, (WHETHER THE FEATURE APPLIES TO BOTH SIDES OF THE DOOR AND/OR IF A DEPTH APPLIES.) MAXIMUM PRODUCT DIMENSIONS ARE SHOWN FOR THE PURPOSE OF VERIFYING FITMENT WITH DOOR FRAME STOPS, DOOR STILE SIZE & LIGHT/LOUVER KITS. IF OPTIONAL LEVERS OR ROSES ARE USED REFERENCE THE RELATED PRODUCT DIMENSIONS TO VERIFY THE FITMENT REQUIREMENTS.
.250
2X 2.313
NOTES: 1. DRAWING IS NOT TO SCALE. 2. PREPARATION DETAILS ARE IN SUPPLEMENT TO ANSI/BHMA A156.115 AND/OR A115W. 3. REFERENCE STRIKE TEMPLATE FOR DETAILS TO PREPARE FRAME. 4.
.156
+.031 THRU 2.125 - .000 2X
OUTSIDE
B
.313
REV F
+.031 X 1.063 - .000
5.375 4.500
.500
2
.125
.125 1.000 THIS SIDE ONLY
.250
SH
2X
.156
4486
2X
DWG No.
2X 6.625
C
CUT .313 THIS SIDE ONLY
INTERPRET DRAWING PER ANSI Y14.5M -1994 UNLESS OTHERWISE SPECIFIED ALL DIMENSION ARE IN INCHES. .XX .01 TOLERANCE .XXX .005 ANGLE 1 FRACTION 1/64
CONFIDENTIAL
8
7
6
5
4
3
THIS DOCUMENT IS THE CONFIDENTIAL PROPERTY OF SARGENT MANUFACTURINGAND IS NOT TO BE REPRODUCED, USED OR DISCLOSED BY ANYONE WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE SARGENT MANUFACTURING COMPANY.
2
DRAWN BY/DATE
SARGENT Manufacturing Company
SG
5/16/08
TCZ
5/21/08
ART.
MJF
5/13/08
TITLE:
CCH
5/22/08
-
-
LB
5/30/08
CHECKED BY/DATE MFG ENG/DATE
FNL APPROVAL/DATE FNL APPROVAL/DATE PROD CTRL/FNL REL
100 Sargent Drive New Haven, CT 06511
KP SERIES BORED LOCK
DOOR MANUFACTURERS TEMPLATE
SIZE DWG No.
D
SCALE:
4486 1:2
1
REV F
SHEET:
2 of 2