INSPECTION REPORT
For the Property at:
123 ANYSTREET MYTOWN, NY
Prepared for: HOME BUYER Inspection Date: Wednesday, October 19, 2016 Prepared by: Jim Freebody
Nassau Home Inspections 135 Aspinwall St Westbury, NY 11590 516 840 9400 www.nshinspection.com
[email protected]
www.nshinspection.com
December 16, 2016 Dear Home Buyer, RE: Report No. 1451, v.3 123 Anystreet Mytown, NY
Your report is now accessible by clicking the link at the bottom of this message - this report is protected and can only be viewed from this link - It will be available online for 180 days. If your inspection included a Termite (Wood Destroying Insect Inspection), it can be found under the appendix tab at the end of the report. To send a full copy of this report to your Realtor or Attorney, simply forward them this email. Our business is mostly on a referral basis. We hope that you were satisfied with our service. Any feedback and referrals are greatly appreciated. We sincerely thank You for your business. Best wishes and good luck in your new home, Sincerely, Jim Freebody on behalf of Nassau Home Inspections
Nassau Home Inspections 135 Aspinwall St Westbury, NY 11590 516 840 9400 www.nshinspection.com
[email protected]
Report No. 1451, v.3
SUMMARY 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Nassau-suffolk Home Inspections wishes to remind you, every home requires a certain amount of ongoing maintenance, such as, clogged drains, servicing of furnaces, air conditioners, water heaters, etc. It is suggested that you budget for regular maintenance/repairs. The following summary is based on a visual inspection of the accessible areas of this property.
Roofing SLOPED ROOFING \ Asphalt shingles Condition: Old, worn out Implication(s): Chance of water damage to contents, finishes and/or structure Location: Garage Task: Replace
Exterior ROOF DRAINAGE \ Downspouts Condition: Downspouts end too close to building Implication(s): Chance of water damage to contents, finishes and/or structure Location: Various Exterior Task: Correct WALLS \ Trim Condition: Rot Implication(s): Chance of water damage to contents, finishes and/or structure | Material deterioration Location: Garage Task: Repair or replace EXTERIOR GLASS \ Glass (glazing) Condition: Putty missing, cracked or deteriorated Implication(s): Chance of water entering building | Increased heating and cooling costs Location: Right Side and Rear Bay Window Exterior Task: Repair or replace EXTERIOR GLASS \ Exterior trim Condition: Missing or loose pieces Implication(s): Cosmetic defects | Chance of water damage to contents, finishes and/or structure Location: Garage Task: Repair or replace EXTERIOR GLASS \ Window wells Condition: Deep Window Well should have protective cover/fencing to prevent falls Location: Various Exterior
Providing great home inspections for every client every time
Page 1 of 38
Report No. 1451, v.3
SUMMARY 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Steps and landings Condition: recommend repointing brick/stone on steps Location: Front and Right Side LANDSCAPING \ Driveway Condition: Deteriorated Asphalt Driveway Location: Right Side Task: Monitor LANDSCAPING \ General Condition: Note: Termite Baiting System installed around exterior perimeter of foundation - Request Disclosure as to reason and if currently under Service Contract. Location: Throughout Exterior
Electrical DISTRIBUTION SYSTEM \ Outlets (receptacles) Condition: old style 2 prong ungrounded outlets Location: Various Task: Upgrade Condition: Loose Implication(s): Electric shock | Fire hazard Location: Bathroom Task: Improve Condition: Ground Fault Circuit Interrupter (GFCI) needed Implication(s): Electric shock Location: Second Floor Bathroom Task: Upgrade Condition: Ground Fault Circuit Interrupter (GFCI) needed Implication(s): Electric shock Location: Kitchen Task: Upgrade
Heating GAS HOT WATER BOILER \ Radiators, convectors and baseboards Condition: Leaning out at top -Not standing up straight Location: Second Floor Bedroom Task: Further evaluation
Providing great home inspections for every client every time
Page 2 of 38
Report No. 1451, v.3
SUMMARY 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Cooling & Heat Pump AIR CONDITIONING \ Life expectancy Condition: Near end of life expectancy Implication(s): Equipment failure | Reduced comfort Task: Monitor
Plumbing WATER HEATER \ Temperature/pressure relief valve Condition: Discharge tube missing Implication(s): Scalding Location: Basement Task: Provide FIXTURES AND FAUCETS \ Faucet Condition: Sink Sprayer taped up Location: Kitchen Task: Repair or replace FIXTURES AND FAUCETS \ Hose bib or bibb Condition: exterior faucet(s) not frost proof type - must be turned off from inside basement during winter to prevent freezing or replace with frost free faucet(s). Location: Various Exterior Task: Upgrade
Interior EXHAUST FANS \ Exhaust fan Condition: Inoperative Implication(s): Chance of condensation damage to finishes and/or structure Location: Kitchen Task: Repair or replace APPLIANCES \ Dryer Condition: Dryer Vent Hose should be made of flexible metal. Location: Basement Task: Replace This concludes the Summary section. The remainder of the report describes each of the home's systems and also details any recommendations we have for improvements. Limitations that restricted our inspection are included as well.
Providing great home inspections for every client every time
Page 3 of 38
Report No. 1451, v.3
ROOFING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description Sloped roofing material:
Approximate age of roof is 5-10 years
Sloped roofing material: Asphalt shingles
Limitations General: The precise age of the roof cannot always be determined, due to certain roof materials, such as slate and wood styles. Leaks in roof and roof flashings may not be discovered at the time of the inspection and/or may sometimes develop after the inspection, due to severe weather conditions or impact. This inspection is not a guarantee against roof leakage in the future.
Recommendations SLOPED ROOFING \ Asphalt shingles Condition: Old, worn out Implication(s): Chance of water damage to contents, finishes and/or structure Location: Garage Task: Replace
Providing great home inspections for every client every time
Page 4 of 38
Report No. 1451, v.3
ROOFING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Providing great home inspections for every client every time
Page 5 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description General:
General Exterior Photos
Gutter & downspout material: Gutter & downspout type: Downspout discharge: Lot slope:
Aluminum
Eave mounted
Above grade
Away from building
Wall surfaces - wood:
Shingles
Driveway:
Asphalt
Walkway:
Concrete
Pressure-treated wood
Ground level
Pressure-treated wood
Deck:
Providing great home inspections for every client every time
Page 6 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Exterior steps:
Concrete
Recommendations ROOF DRAINAGE \ Downspouts Condition: Downspouts end too close to building Implication(s): Chance of water damage to contents, finishes and/or structure Location: Various Exterior Task: Correct
Providing great home inspections for every client every time
Page 7 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
WALLS \ Trim Condition: Rot Implication(s): Chance of water damage to contents, finishes and/or structure | Material deterioration Location: Garage Task: Repair or replace
EXTERIOR GLASS \ Glass (glazing) Condition: Putty missing, cracked or deteriorated Implication(s): Chance of water entering building | Increased heating and cooling costs Location: Right Side and Rear Bay Window Exterior Task: Repair or replace
Providing great home inspections for every client every time
Page 8 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
EXTERIOR GLASS \ Exterior trim Condition: Missing or loose pieces Implication(s): Cosmetic defects | Chance of water damage to contents, finishes and/or structure Location: Garage Task: Repair or replace
Providing great home inspections for every client every time
Page 9 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
EXTERIOR GLASS \ Window wells Condition: Keep window wells free from debris - bottom of well should be 6-8 inches below window frames
Condition: Deep Window Well should have protective cover/fencing to prevent falls Location: Various Exterior
Providing great home inspections for every client every time
Page 10 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Steps and landings Condition: recommend repointing brick/stone on steps Location: Front and Right Side
LANDSCAPING \ Driveway Condition: Deteriorated Asphalt Driveway Location: Right Side Task: Monitor
Providing great home inspections for every client every time
Page 11 of 38
Report No. 1451, v.3
EXTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
LANDSCAPING \ General Condition: Note: Termite Baiting System installed around exterior perimeter of foundation - Request Disclosure as to reason and if currently under Service Contract. Location: Throughout Exterior
Providing great home inspections for every client every time
Page 12 of 38
Report No. 1451, v.3
STRUCTURE 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description Configuration:
Basement
Foundation material: Floor construction:
Poured concrete Joists
Exterior wall construction: Roof and ceiling framing:
Steel columns
Laminated wood beams
Subfloor - plank
Wood frame original cedar shingle roofing, used as roof sheathing
Roof and ceiling framing: Rafters/roof joists
Limitations General: Please note that an inspection is not a guarantee that you do not have termites or damage in visually inaccessible areas, such as inside walls or behind finished basement surfaces. This is one reason why an annual Termite or Carpenter Ant inspection is valuable. Keep records of all such inspections. Inspection limited/prevented by:
Basement Mostly Finished Living Space
Providing great home inspections for every client every time
Page 13 of 38
Report No. 1451, v.3
STRUCTURE 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Providing great home inspections for every client every time
Page 14 of 38
Report No. 1451, v.3
ELECTRICAL 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description General: The National Fire Protection Agency (NFPA) urges homeowners to replace smoke detectors and CO detectors more than 10 years old, and to replace all smoke detectors when moving into a new residence unless you know that the smoke detectors and CO detectors are new. Replacements are inexpensive and readily available. Service entrance cable and location: Overhead copper
Service size:
100 Amps (240 Volts)
Main disconnect/service box rating:
100 Amps
Main disconnect/service box type and location: Breakers - basement
System grounding material and type:
Copper - water pipe and ground rod
Providing great home inspections for every client every time
Page 15 of 38
Report No. 1451, v.3
ELECTRICAL 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Distribution wire material and type: Copper - non-metallic sheathed Copper - metallic sheathed
Circuit interrupters: Ground Fault (GFCI) & Arc Fault (AFCI): Ground Fault (GFCI) & Arc Fault (AFCI): Gro und Faulted outlets(GFCI) and/or breakers are required for safety, in all interior and exterior areas where water will be in contact with an electrical power source. Standard cover plates should be labeled for "GFCI" when wired on the GFCI circuit. Proper GFCI functionality may not always be fully tested at the time of the inspection because GFCI resets may be hidden and not able to be reset. Smoke detectors:
Present
Recommendations DISTRIBUTION SYSTEM \ Outlets (receptacles) Condition: old style 2 prong ungrounded outlets Location: Various Task: Upgrade Condition: Loose Implication(s): Electric shock | Fire hazard Location: Bathroom Task: Improve
Providing great home inspections for every client every time
Page 16 of 38
Report No. 1451, v.3
ELECTRICAL 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Condition: Ground Fault Circuit Interrupter (GFCI) needed Implication(s): Electric shock Location: Second Floor Bathroom Task: Upgrade
Providing great home inspections for every client every time
Page 17 of 38
Report No. 1451, v.3
ELECTRICAL 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Condition: Ground Fault Circuit Interrupter (GFCI) needed Implication(s): Electric shock Location: Kitchen Task: Upgrade
Providing great home inspections for every client every time
Page 18 of 38
Report No. 1451, v.3
HEATING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description General: Exterior Gas Main - Recommend keeping an adjustable wrench in a zip-lock bag, attached to meter, to facilitate emergency gas shut-off.
Fuel/energy source: System type:
Gas
Boiler
Boiler manufacturer: Heat distribution:
Radiators
Approximate capacity: Efficiency:
Slant/Fin
150,000 BTU/hr
Conventional
Exhaust venting method: Approximate age:
Natural draft
6 years
Typical life expectancy: Boiler (cast iron) 25 to 50 years
Providing great home inspections for every client every time
Page 19 of 38
Report No. 1451, v.3
HEATING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Main fuel shut off at: Fireplace:
Basement
Masonry wood burning fireplace
Providing great home inspections for every client every time
Page 20 of 38
Report No. 1451, v.3
HEATING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Chimney/vent:
Masonry
Chimney liner: Metal Clay
Limitations General: Note: Flue not inspected. Annual cleaning recommended. Zone, boiler and radiator valves: Zone valves, radiator valves, circulators, integrated humdification units and internal parts of the heating system are inspected for proper functionality, but can not be fully tested, as full tests would be considered invasive.
Providing great home inspections for every client every time
Page 21 of 38
Report No. 1451, v.3
HEATING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Recommendations GAS HOT WATER BOILER \ Radiators, convectors and baseboards Condition: Leaning out at top -Not standing up straight Location: Second Floor Bedroom Task: Further evaluation
Providing great home inspections for every client every time
Page 22 of 38
Report No. 1451, v.3
COOLING & HEAT PUMP 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description Air conditioning type: Manufacturer:
Air cooled
Bryant
Cooling capacity:
24,000 BTU/hr
Compressor type:
Electric
Compressor approximate age:
19 years
Typical life expectancy: 15 to 20 years Note: Central A/C for top floor only
Recommendations AIR CONDITIONING \ Life expectancy Condition: Near end of life expectancy Implication(s): Equipment failure | Reduced comfort Task: Monitor
Providing great home inspections for every client every time
Page 23 of 38
Report No. 1451, v.3
INSULATION AND VENTILATION 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description Attic/roof insulation material:
Glass fiber
Attic/roof ventilation: Gable vent Power ventilator
Providing great home inspections for every client every time
Page 24 of 38
Report No. 1451, v.3
PLUMBING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description Water supply source:
Public
Service piping into building:
Copper
Supply piping in building:
PEX (Cross-linked polyethylene)
Supply piping in building:
Copper
Main water shut off valve at the: Basement Meter
Water flow and pressure:
Typical for neighborhood
Water heater fuel/energy source: Water heater type:
Gas
Conventional
Water heater exhaust venting method: Water heater manufacturer: Tank capacity:
Natural draft
General Electric
50 gallons
Water heater approximate age:
6 years
Typical life expectancy: 8 to 12 years
Providing great home inspections for every client every time
Page 25 of 38
Report No. 1451, v.3
PLUMBING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Waste disposal system:
Public
Waste and vent piping in building:
PVC plastic
Cast Iron
Limitations General: The following plumbing system items are not covered, as they are beyond the scope of this inspection; Isolated or hidden plumbing pipes and relief valves. Main exterior water shut-off valves will not be turned on/off. Tub/sink overflows will not be tested. Water quality not tested. Water treatment equipment will not be inspected. Solar and Geo-Thermal plumbing, heating and cooling systems are not inspected. French Drain Systems cannot be pressure tested and cannot be tested for their performance. It is recommended that they be fully tested and inspected by a professional technician. Cesspools cannot be opened.
Recommendations WATER HEATER \ Temperature/pressure relief valve Condition: Discharge tube missing Implication(s): Scalding Location: Basement Task: Provide
Providing great home inspections for every client every time
Page 26 of 38
Report No. 1451, v.3
PLUMBING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
FIXTURES AND FAUCETS \ Faucet Condition: Sink Sprayer taped up Location: Kitchen Task: Repair or replace
Providing great home inspections for every client every time
Page 27 of 38
Report No. 1451, v.3
PLUMBING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
FIXTURES AND FAUCETS \ Hose bib or bibb Condition: exterior faucet(s) not frost proof type - must be turned off from inside basement during winter to prevent freezing or replace with frost free faucet(s). Location: Various Exterior Task: Upgrade
Providing great home inspections for every client every time
Page 28 of 38
Report No. 1451, v.3
PLUMBING 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Providing great home inspections for every client every time
Page 29 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Description General:
General Interior Photos
Providing great home inspections for every client every time
Page 30 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
General:
General Interior Photos
Providing great home inspections for every client every time
Page 31 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Providing great home inspections for every client every time
Page 32 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
Hardwood
Laminate
Ceramic
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Major floor finishes:
Major wall and ceiling finishes:
Plaster/drywall
Windows:
Vinyl
Glazing:
Single/double hung Double
Exterior doors - type/material:
Metal/Glass
Exterior doors - type/material:
Hinged
Oven type:
Conventional
Oven fuel:
Gas
Range fuel:
Gas
Appliances:
Refrigerator
Range hood
French
Storm
Wood
Garage door - wood
Dishwasher
Providing great home inspections for every client every time
Page 33 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Laundry facilities: Washer Laundry tub Hot/cold water supply Dryer Vented to outside 120-Volt outlet Waste standpipe
Limitations Inspection limited/prevented by:
Garage filled with personal belongings
Not tested/not in service: Range
Providing great home inspections for every client every time
Page 34 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Gas turned off - not tested
Recommendations EXHAUST FANS \ Exhaust fan Condition: Inoperative Implication(s): Chance of condensation damage to finishes and/or structure Location: Kitchen Task: Repair or replace
APPLIANCES \ Dryer Condition: Dryer Vent Hose should be made of flexible metal. Location: Basement Task: Replace
Providing great home inspections for every client every time
Page 35 of 38
Report No. 1451, v.3
INTERIOR 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
END OF REPORT
Providing great home inspections for every client every time
Page 36 of 38
Report No. 1451, v.3
APPENDIX 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
10/19/2016
N/A Nassau-suffolk Home Inspections 135 Aspinwall Street Westbury, NY 11590 (515) 894-9400
James Freebody
16000005080
123 Anystreet, Mytown, NY
Single Family Residence
Termite Baiting System Installed Around Exterior
Basement Mostly Finished Living Space 1,3,4,5,6,7,8
Providing great home inspections for every client every time
Page 37 of 38
Report No. 1451, v.3
APPENDIX 123 Anystreet, Mytown, NY SUMMARY
ROOFING
www.nshinspection.com
October 19, 2016
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING
INSULATION
PLUMBING
INTERIOR
APPENDIX
Providing great home inspections for every client every time
Page 38 of 38